Waldent Maxcure 3 Light Cure Unit
Original price was: $71.80.$64.69Current price is: $64.69.
In Stock-
Curing Light Mode Applications
FULL : For general applications
PULSE : For more gentle processing, designed for reducing the shrinkage of composite
RAMP : First 0-5 seconds are ramped for more gentle processing,designed for patients sensitive to heat
10 in stock
Description
Light cure unit – The Product is suppose to be used in hospital and dental clinic,should be used by trained qualified dentist.This curing light is used for the principal of ray radiation to solidify the light-sensitive resin by shooting at it in a short time,is used to restore teeth
Key Specification
Environmental Factors
Operation: 5°C — 40°C / 30% — 75% relative humidity / 70 – 106KPa atmospheric pressure
Transportation and Storage: -20°C – +40°C /10% 93% relative humidity/70 106KPa
atmospheric pressure.
Depth of cure
- F.O Light Guide : 8 mm (dia.)
- Light Wavelength : 430 – 480nm
- Application : General
- Full : 1,200mW/cm2+10%for 5, 10, 15, ,20 seconds
- Pulse : 0-1, 200mW/cm2 + 10%for 5, 10, 15, 20, seconds
- Ramp : 1st five seconds from 0-1200mW/cm2+10% next 5, 10 , 15, 20, seconds 1200mW/cm2+10%
- Model: MaxCure3
- Power Input: 100-240VAC, 50Hz/60Hz
- Power Output: 5V DC/1A
- Wave length: 430 nm-480 nm
- Light intensity: 0-1200mW/cm²
Packaging
- 1 x Main Unit
- 1 x Optical Fiber
- 1 x Adapter
- 1 x Light Hood
- 1 x Instructions Manual
Direction To Use
A. CHARGING:
Plug the Type-C power cord directly into the curing light handpiece. Once connected,
handpiece display screen will be on and shows CH (charging) during the whole charging
process. When battery is full, charging will stop automatically, and handpiece display screen
shows FU (Full).
B. CURING LIGHT HANDPIECE:
- Insert the fibre optic light guide into the curing light handpiece with a TWISTING motion.Ensure the fibre optic guide fits securely into the curing light handpiece.
- The battery is not fully charged prior to shipment. Please charge the battery for a minimum of 2 hours prior to the first use.
- The curing light circuitry will automatically compensate for power fluctuation during use for a constant light intensity output.
- Continually charging the curing light will not affect the life of the battery as it has a built-in safety function that will stop charging the battery when it is full.
- The light intensity should be checked regularly with a light intensity meter.
Changing Of Settings And Use
- Activate the curing light by pressing the ON/OFF or TIME/MODE switch ONCE.
- The curing light is preset in the factory to the “FULL” mode for 10 seconds.
- Press and hold the TIME/MODE switch for 2 seconds to change the mode.Press the TIME/MODE switch repeatedly to locate the desired time for the “FULL””PULSE”or “RAMP” mode.
- Every start and end of a programme or every change of time or mode,will be signaled with a “beep”.
- The curing light will automatically turn off if it is not in operation for 1 minute. It will keep the last selected programme in memory once restarted.
- Put on the disposable curing light sleeve to cover the entire curing light for cross infection control.
- Put the protective light shield onto the light guide tip until it is firmly held on the curing light.The curing light is now ready for use.
- Press the ON/OFF or TIME/MODE switch to activate the curing light if no indicator light is on.When the preparation for light curing is ready,